July - December 2025

Vol. 5, Issue 2

Different Types of STR Kits Available in India: Forensic Applications, Advantages, and Limitations

The international standard for human DNA profiling in criminal proceedings, kinship analysis, and missing person identification is short tandem repeats, or STRs. Commercial multiplex STR kits, designed for capillary electrophoresis (CE) equipment, enable the simultaneous amplification of 15–31 loci with internal size standards and controls.

In India, STR profiling is carried out mainly in:

  • Central Forensic Science Laboratories (CFSLs).
  • State and Regional Forensic Science Laboratories (FSLs/RFSLs).

Multiple imported and now some indigenous STR kits are in routine use, and Indian population/validation studies show active deployment of these kits in forensic laboratories across several states.

According to Section 45 of the Indian Evidence Act, 1872 (renumbered as Section 39 in the Bharatiya Sakshya Adhiniyam, 2023), DNA profiling is considered expert testimony in Indian courts. As long as the chain of custody and methodology are trustworthy, expert scientific opinions—including DNA findings from certified labs—are accepted.

Courts do not prescribe or restrict specific commercial kits; they examine whether:

  1. The technique (STR-based DNA profiling) is scientifically accepted.
  2. The laboratory is competent/accredited and follows validated SOPs.
  3. The chain of custody and quality control are adequate.

Therefore, any STR kit that is scientifically validated, used in an accredited FSL with proper documentation, can be admissible in Indian courts.

Determination of Tamsulosin Hydrochloride from Pharmaceutical Formulation (Urimax 0.4) Using Thin Layer Chromatography

A common medication used to treat benign prostatic hyperplasia is tamsulosin hydrochloride, a selective α α-adrenergic receptor antagonist (5,7). Its detection in pharmaceutical formulations and biological samples is crucial in situations of drug abuse, overdose, and medico-legal investigations in forensic and clinical toxicology (21,22). Thin Layer Chromatography (TLC) provides a quick, affordable, and dependable screening procedure, even if instrumental techniques like HPLC and LC- MS are frequently used (3,4,16).

In this investigation, tamsulosin hydrochloride from a commercial modified-release capsule formulation (URIMAX 0.4, 400 µg) was identified using a straightforward TLC approach (11,12,14). Using a chloroform solvent solution, chromatographic separation was accomplished on silica gel 60 F254 plates: The ratio of methanol to ammonia (25%) is 8:2:0.2 (v/v/v) (16,18). The existence of the basic alkaloidal substance was confirmed by visualization under UV light at 254 nm and by spraying with Dragendorff reagent, which formed a distinctive orange-brown spot (10,18,20). For regular forensic screening of tamsulosin in pharmaceutical and toxicological samples, the established approach is straightforward, sensitive, and appropriate (2,3,4).

Thin-Layer Chromatographic Analysis of Dynapar-AQ Injection After Liquid-Liquid Extraction

A simple and cost-effective thin-layer chromatography (TLC) method was developed for the separation and presumptive identification of the active constituent(s) of Dynapar-AQ injection following liquid– liquid extraction (LLE) and concentration [1,4,10,16]. The injectable formulation (1 mL) was diluted, acidified, and extracted using ethyl acetate (3 × 5 mL). The pooled organic phase was dried over anhydrous sodium sulfate, concentrated, and reconstituted in acetone according to established extraction and sample clean-up procedures [4,6,12]. Chromatographic separation was carried out on silica gel plates using two mobile phases: ethyl acetate : methanol : glacial acetic acid (8:2:0.1) and chloroform : methanol : acetic acid (9:1:0.1), selected based on previously reported TLC methodologies [1,3,5,10].

Visualization was achieved under ultraviolet light (254 and 366 nm) and by spraying with Dragendorff reagent [5,8,9]. The Dynapar standard and sample exhibited co-chromatographic behavior, producing a single major spot with reproducible Rf values, thereby supporting presumptive identification. The developed LLE–TLC method proved to be rapid, inexpensive, and reproducible, and is suitable as a screening technique in forensic and toxicological laboratories [11,16,19]. Methodological choices regarding solvent systems, extraction conditions, and visualization reagents were guided by established TLC and forensic extraction practices reported in the literature [1,3,4,10,16].